thermal centers

Filter:

Showing all 184 results

11 959 426

including VAT 0%
  • Bitumen melting capacity, t/h 6
  • Daily bitumen melting capacity, m3/day up to 120
  • Bitumen shipment capacity, m3/h 25-30
  • Installed power consumption no more than, kW 40
  • Installed thermal power, kW 500
  • Natural gas consumption, nm.cub/h 69
  • Natural gas connection pressure, kPa 4-36
  • Объем камеры, м3 90
  • Вместимость камеры, м3 Teeth 40
  • Steam generators PG-500 are not subject to registration with Rostekhnazor, because operating pressure of the steam generator is less than 0.07 MPa. 500
  • DF consumption (no more), kg/h (l/h) 32 (39)
  • Gas consumption (no more), nm3 Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 41
  • Operating steam temperature, °C 110
  • Установленная мощность электропитания, кВт 2
  • Thermal power, kW 50
  • Outlet air flow up to, m3/hour 2200-3700
  • Air pressure at the outlet of the DVT, no more than, Pa 1200-600
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 80
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 50
  • Outlet air flow up to, m3/hour 2200-3700
  • Air pressure at the outlet of the DVT, no more than, Pa 1200-600
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 80
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 100
  • Outlet air flow up to, m3/hour 5000-7000
  • Air pressure at the outlet of the DVT, no more than, Pa 900-1100
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 80
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 150
  • Outlet air flow up to, m3/hour 5000-7000
  • Air pressure at the outlet of the DVT, no more than, Pa 900-1100
  • Air heating delta, °C 60
  • Maximum outlet air temperature, °C 100
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 250
  • Outlet air flow up to, m3//time 7000-14000
  • Air pressure at the outlet of the DVT, no more than, Pa 500-1500
  • Air heating delta, °C 50
  • Maximum outlet air temperature, °C 90
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually

1 588 900

including VAT 0%
  • Thermal power, kW 250
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 5,300
  • Fan air flow, m3/hour 2800
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7
  • Thermal power, kW 250
  • Outlet air flow up to, m3/hour 8500-18000
  • Air pressure at the outlet of the DVT, no more than, Pa 500-1000
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 80
  • Time to reach operating mode, no more, min 10
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 250
  • Outlet air flow up to, m3/hour 8500-18000
  • Air pressure at the outlet of the DVT, no more than, Pa 500-1000
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 80
  • Time to reach operating mode, no more, min 10
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 300
  • Air flow at the DHW outlet, m3/hour 10000-20000
  • Pressure at the outlet of the installation, Pa 50
  • The pressure fan Pa 200
  • Outlet air temperature, no more than, °C 90
  • Time to reach operating mode, no more, min 15
  • Gas flow max., nm3/hour 8..35

2 053 200

including VAT 0%
  • Thermal power, kW 250
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 5,300
  • Fan air flow, m3/hour 2800
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7
  • Thermal power, kW 450
  • Outlet air flow up to, m3/hour 14400-41000
  • Air pressure at the outlet of the DVT, no more than, Pa 750-1130
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 70
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually
  • Thermal power, MW (Gcal) 0,2 (0,17)
  • DHW capacity (+5/+65), m3/hour 0,5
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 1,000
  • Fuel consumption for gas equipment, nm.cub./hour 24
  • Fuel consumption for diesel equipment, kg/hour 19
  • Installed thermal capacity, MW (Gcal) 3,1 (2,66)
  • Nameplate efficiency, % 90
  • Certified fuel consumption: min/max, nm.cub./hour 50/367
  • Installed steam boilers KPSD-2000x2
  • Installed gas burners Baltur TBG 210P
  • Installed gas trains MM420
  • Water treatment softening with pH adjustment DIASEL
  • Installed thermal capacity, MW (Gcal) 3,1 (2,66)
  • Nameplate efficiency, % 90
  • Certified fuel consumption: min/max, nm.cub./hour 50/367
  • Installed steam boilers KPSD-2000x2
  • Installed gas burners Baltur TBG 210P
  • Installed gas trains MM420
  • Water treatment softening with pH adjustment DIASEL
  • Thermal power, MW (Gcal) 0,174(0,15)
  • Temperature graph (supply/return), °C 300/250
  • Installed thermal oil boiler KTM-0.15
  • Installed burner Baltur BТG 20P
  • Type of design fuel Natural gas GOST 5542-2022
  • Certified gas consumption: min/max, nm.cub/h 10/24
  • Installed fuel filter Fine cleaning
  • Thermal power, MW (Gcal) 0,3(0,26)
  • Temperature graph (supply/return), °C 300/250
  • Installed thermal oil boiler КТМ-0,15 (2шт.)
  • Installed burner Baltur BТG 20P (2шт.)
  • Type of design fuel Natural gas GOST 5542-2022
  • Гидравлические характеристики, МПа Термомасляная часть (подача/обратка) 0,3/0,05
  • Boiler room coolant capacity, cubic meters 0.4
  • Thermal power, MW (Gcal) 0,65(0,56)
  • Temperature graph (supply/return), °C 300/250
  • Installed thermal oil boiler KTM-0.65
  • Installed burner Еcoflam BLU 700.1LN PRE TL
  • Type of design fuel Natural gas GOST 5542-2022
  • Certified gas consumption: min/max, nm.cubic/hour 16/80
  • Installed boiler KTM-0.65
  • Thermal power, MW (Gcal) 0,8(0,69)
  • Temperature graph (supply/return), °C 300/250
  • Installed thermal oil boiler KTM-1.0
  • Installed burner Baltur TBG 120 ME
  • Type of design fuel Natural gas GOST 5542-2022
  • Hydraulic characteristics, MPa heat oil part (supply/return) 0,25/0,05;
  • Boiler room coolant capacity, cubic meters 1
  • Thermal power, MW (Gcal) 1,16(1,0)
  • Temperature graph (supply/return), °C 300/250
  • Installed thermal oil boiler KTM-1.0
  • Installed burner Baltur TBG 150P
  • Type of design fuel Natural gas GOST 5542-2022
  • Power supply 3f, 230/400V, 50Gc
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) Automatic
  • Thermal power, MW (Gcal) 3(2,58)
  • Temperature graph (supply/return), °C 300/250
  • Installed thermal oil boiler КТМ-1,5(2шт.)
  • Installed burner Baltur ТBML 200MC, Baltur ТBG 210P
  • Type of design fuel Natural gas GOST 5542-2022
  • Паспортный расход газа по котельной: min/max, нм.куб/час 100/411
  • Lower calorific value of design fuel, Kcal/nm.cub. 8,000
  • Thermal power, kW 450
  • Outlet air flow up to, m3/hour 8700-18000
  • Air pressure at the outlet of the DVT, no more than, Pa 500-1500
  • Air heating delta, °C 70
  • Maximum outlet air temperature, °C 110
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually

2 181 800

including VAT 0%
  • Useful volume of container, m3 45
  • Nominal capacity volume, m3 48
  • Heating area, m2 30
  • Oil registers, quantity, pcs 2
  • Coolant volume in registers, l 350
  • Ventilation system hatch ⌀600 mm and round deflector DN = 250 mm
  • Thermal insulation URSA basalt, mm 80

1 277 300

including VAT 0%
  • Useful volume of container, m3 30
  • Nominal capacity volume, m3 31
  • Oil registers, quantity, pcs 2
  • Coolant volume in registers, l 250
  • Ventilation system hatch ⌀600 mm and round deflector DN = 250 mm
  • Thermal insulation URSA basalt, mm 80 мм
  • housing material steel St.09G2S sheet, s=4 mm of the shell, s=6 mm of the bottom
  • Heat production of the boiler, Gcal/h; 00.3
  • Bitumen pump performance, cube m; 15,7
  • Maximum oil temperature, ° C +300/+250
  • Operation temperature +5 ...+40 ° C
  • Useful volume of bitumen storage, cube. m 28
  • The volume of the coolant in the installation, cube. m 0,7
  • Thermal insulation URSA basalt, mm 50

1 040 500

including VAT 0%
  • Productivity, m 2
  • Productivity, m 2
  • Productivity, m Side, top
  • Side, top
  • Side, top2 44
  • Side, top2 10
  • Upper tier, m2 34

1 582 200

including VAT 0%
  • Productivity, m 1
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,1
  • Installed power, kW 125,5
  • 23 866 $ Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Maximum oil heating temperature, °C 23 866 $
  • The volume of the coolant m3 0.8

2 133 000

including VAT 0%
  • Thermal power, kW 450
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 9,600
  • Fan air flow, m3/hour 5,000
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7

2 762 900

including VAT 0%
  • Thermal power, kW 450
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 9,600
  • Fan air flow, m3/hour 5,000
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7
  • Thermal power, kW 450
  • Outlet air flow up to, m3/hour 8700-18000
  • Air pressure at the outlet of the DVT, no more than, Pa 500-1500
  • Air heating delta, °C 70
  • Maximum outlet air temperature, °C 110
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually,
  • Thermal power, MW 0,1
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 5
  • Boiler internal volume, m3 0,13
  • The volume of the ball, m3 0,127
  • Thermal power, MW 0,35
  • Product temperature:
  • At the inlet – not less than °С +5
  • Output – no more than °C +70
  • Type of intermediate coolant steam
  • Intermediate coolant heating temperature, °C +110
  • Thermal power of the burner, not less, MW 0,39
  • Thermal power, MW 0,25
  • Product temperature:
  • At the inlet – not less than °С +5
  • Output – no more than °C +70
  • Type of intermediate coolant water, liquids according to GOST 33591-2015
  • Intermediate coolant heating temperature, °C +95
  • Thermal power of the burner, not less, MW 0,278
  • Thermal power, Gcal/h (MW) 1 Gcal/h (1.16 MW)
  • Product temperature:
  • At the inlet – not less than °С +5
  • Output – no more than °C +70
  • Type of intermediate coolant thermal oil
  • Intermediate coolant heating temperature, °C +100
  • Thermal power of the burner, not less, MW 1,281

1 566 200

including VAT 0%
  • Теплопроизводительность, МВт/ч (ГКал/ч) 0,2 (0,17)
  • Температура теплоносителя, до, °С 105
  • Максимальное давление теплоносителя, МПа 0,6
  • Расход газа, нм куб/ч 24
  • Climatic version U1
  • Установленная мощность (3ф 220/380В, 50 Гц), кВт 5
  • KPD% 90
  • Thermal power, MW 0,25
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 10
  • Boiler internal volume, m3 0,32
  • The volume of the ball, m3 0,183
  • Thermal power, MW 0,5
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 16
  • Boiler internal volume, m3 0,55
  • The volume of the ball, m3 0,471
  • Thermal power, MW 0,7
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 21
  • Boiler internal volume, m3 1,2
  • The volume of the ball, m3 0,557
  • Thermal power, MW 1
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 27
  • Boiler internal volume, m3 1,4
  • The volume of the ball, m3 0,964
  • Thermal power, MW 1,5
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 35
  • Boiler internal volume, m3 1.8
  • The volume of the ball, m3 1,449
  • Thermal power, MW 2
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 46
  • Boiler internal volume, m3 2,7
  • The volume of the ball, m3 2,375
  • Thermal power, MW 3
  • Design pressure, MPa 0,6
  • Test pressure, MPa 0,9
  • Maximum coolant temperature, °C 105
  • Internal heating area, m2 85
  • Boiler internal volume, m3 2,7
  • The volume of the ball, m3 1,828

819 700

including VAT 0%
  • Steam generators PG-500 are not subject to registration with Rostekhnazor, because operating pressure of the steam generator is less than 0.07 MPa. 500
  • DF consumption (no more), kg/h (l/h) 32 (39)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 41
  • Thermal power of the steam generator, MW (GCal) 0,35(0,3)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,39
  • Operating pressure, MPa 0,05
  • Steam generators PG-500 are not subject to registration with Rostekhnazor, because operating pressure of the steam generator is less than 0.07 MPa. 500
  • DF consumption (no more), kg/h (l/h) 32 (39)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 41
  • Thermal power of the steam generator, MW (GCal) 0,35(0,3)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,39
  • Operating pressure, MPa 0,05
  • Thermal power, kW 600
  • Outlet air flow up to, m3/hour 10000-28000
  • Air pressure at the outlet of the DVT, no more than, Pa 900-1300
  • Air heating delta, °C 70
  • Maximum outlet air temperature, °C 110
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually,

2 704 900

including VAT 0%
  • Thermal power, kW 600
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 12800
  • Fan air flow, m3/hour 6800
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7
  • Thermal power, kW 600
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 12800
  • Fan air flow, m3/hour 6800
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7
  • Thermal power, kW 600
  • Outlet air flow up to, m3/hour 10000-28000
  • Air pressure at the outlet of the DVT, no more than, Pa 900-1300
  • Air heating delta, °C 70
  • Maximum outlet air temperature, °C 110
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually

4 098 300

including VAT 0%
  • Thermal power, kW 800
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 16500
  • Fan air flow, m3/hour 9,000
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7
  • Thermal power, kW 800
  • Outlet air flow up to, m3//time 50000-76000
  • Air pressure at the outlet of the DVT, no more than, Pa 2,000
  • Air heating delta, °C 40
  • Maximum outlet air temperature, °C 80
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually
  • Thermal power, kW 1,000
  • Outlet air flow up to, m3/hour 7500-24500
  • Air pressure at the outlet of the DVT, no more than, Pa 1280-1800
  • Air heating delta, °C 110
  • Maximum outlet air temperature, °C 120
  • Time to reach operating mode, no more, min 7
  • Gas pressure for heat generator, mbar individually,

3 688 525

including VAT 0%
  • Thermal power, kW 2x600
  • Air temperature at the outlet of the DVT, °C 120 (+/-10)
  • Fuel used (depending on burner) gas/diesel
  • Diesel consumption, no more, kg/h 60-120
  • Gas consumption, no more, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 60-150
  • Outlet cross-sectional area, m2 2
  • Time to reach operating mode, no more, min 7

1 167 900

including VAT 0%
  • Steam generators PG-500 are not subject to registration with Rostekhnazor, because operating pressure of the steam generator is less than 0.07 MPa. 1,000
  • DF consumption (no more), kg/h (l/h) 69 (83)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 88
  • Thermal power of the steam generator, MW (GCal) 0,74(0,64)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,83
  • Operating pressure, MPa 0,05
  • Steam production max, kg h 1,000
  • DF consumption (no more), kg/h (l/h) 69 (83)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 88
  • Thermal power of the steam generator, MW (GCal) 0,74(0,64)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,83
  • Operating pressure, MPa 0,05

1 524 200

including VAT 0%
  • Steam generators PG-500 are not subject to registration with Rostekhnazor, because operating pressure of the steam generator is less than 0.07 MPa. 1,500
  • DF consumption (no more), kg/h (l/h) 103 (125)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 132
  • Thermal power of the steam generator, MW (GCal) 1,12(0,96)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,24
  • Operating pressure, MPa 0,05
  • Steam production max, kg h 1,500
  • DF consumption (no more), kg/h (l/h) 103 (125)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 132
  • Thermal power of the steam generator, MW (GCal) 1,12(0,96)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,24
  • Operating pressure, MPa 0,05

1 679 300

including VAT 0%
  • Steam production max, kg h 2,000
  • DF consumption (no more), kg/h (l/h) 138 (166)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 176
  • Thermal power of the steam generator, MW (GCal) 1,49(1,28)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,66
  • Operating pressure, MPa 0,05

4 370 900

including VAT 0%
  • Thermal power, kW 1,000
  • Outlet air flow up to, m3/hour (taking into account air expansion at maximum heating delta) 20,000
  • Fan air flow, m3/hour 10,000
  • Air heating delta, °C 210
  • Air pressure at the outlet of the DVT, no more than, Pa 11500
  • Maximum outlet air temperature, °C 170
  • Time to reach operating mode, no more, min 7

2 003 500

including VAT 0%
  • Nominal steam output, kg/h 150
  • DF consumption (no more), kg/h 11
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 9
  • Thermal power of the steam generator, MW (GCal) 0,13 (0,11)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,13
  • Operating pressure, MPa 0,9

2 138 700

including VAT 0%
  • Nominal steam output, kg/h 150
  • DF consumption (no more), kg/h 11
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 9
  • Thermal power of the steam generator, MW (GCal) 0,114 (0,1)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,13
  • Operating pressure, MPa 0,9
  • Steam production max, kg h 500
  • DF consumption (no more), kg/h (l/h) 35 (43)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 45
  • Thermal power of the steam generator, MW (GCal) 0,38(0,33)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,43
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 500
  • DF consumption (no more), kg/h (l/h) 35 (43)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 45
  • Thermal power of the steam generator, MW (GCal) 0,38(0,33)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,43
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 500
  • DF consumption (no more), kg/h (l/h) 36 (43)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 45
  • Thermal power of the steam generator, MW (GCal) 0,39 (0,33)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,43
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 500
  • DF consumption (no more), kg/h (l/h) 36 (43)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 45
  • Thermal power of the steam generator, MW (GCal) 0,39 (0,33)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,43
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 1,000
  • DF consumption (no more), kg/h (l/h) 71 (85)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 90
  • Thermal power of the steam generator, MW (GCal) 0,76(0,66)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,85
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 1,000
  • DF consumption (no more), kg/h (l/h) 71 (85)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 90
  • Thermal power of the steam generator, MW (GCal) 0,76(0,66)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,85
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 1,000
  • DF consumption (no more), kg/h (l/h) 71 (86)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 91
  • Thermal power of the steam generator, MW (GCal) 0,77(0,66)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,86
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 1,000
  • DF consumption (no more), kg/h (l/h) 71 (86)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 91
  • Thermal power of the steam generator, MW (GCal) 0,77(0,66)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 0,86
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 1,500
  • DF consumption (no more), kg/h (l/h) 106 (128)
  • Gas consumption (no more), nm.cub/h 135
  • Thermal power of the steam generator, MW (GCal) 1,14(0,98)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,27
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 1,500
  • DF consumption (no more), kg/h (l/h) 106 (128)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 135
  • Thermal power of the steam generator, MW (GCal) 1,14(0,98)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,27
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 1,500
  • DF consumption (no more), kg/h (l/h) 107 (129)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 136
  • Thermal power of the steam generator, MW (GCal) 1,15(0,99)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,29
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 1,500
  • DF consumption (no more), kg/h (l/h) 107 (129)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 136
  • Thermal power of the steam generator, MW (GCal) 1,15(0,99)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,29
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 2,000
  • DF consumption (no more), kg/h (l/h) 141 (170)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 180
  • Thermal power of the steam generator, MW (GCal) 1,52(1,31)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,69
  • Operating pressure, MPa 0,6
  • Steam output, kg/h 2,000
  • DF consumption (no more), kg/h (l/h) 141 (170)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 180
  • Thermal power of the steam generator, MW (GCal) 1,52(1,31)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,69
  • Operating pressure, MPa 0,6
  • Steam production max, kg h 2,000
  • DF consumption (no more), kg/h (l/h) 143 (172)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 182
  • Thermal power of the steam generator, MW (GCal) 1,54(1,32)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,71
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 2,000
  • DF consumption (no more), kg/h (l/h) 143 (172)
  • Gas consumption (no more), nm.3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 182
  • Thermal power of the steam generator, MW (GCal) 1,54(1,32)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,71
  • Operating pressure, MPa 1,3
  • Steam production max, kg h 2,000
  • DF consumption (no more), kg/h (l/h) 138 (166)
  • Gas consumption (no more), nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 176
  • Thermal power of the steam generator, MW (GCal) 1,49(1,28)
  • Diesel burner Baltur 90
  • Thermal power of the burner, MW 1,66
  • Operating pressure, MPa 0,05

1 408 800

including VAT 0%
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,21
  • Thermal power, MW 0,25
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 0,278
  • Diesel fuel consumption, kg/h 23
  • Diesel fuel consumption, l/hour 28
  • Methane consumption, nm3/hour 30
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,21
  • Thermal power, MW 0,25
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 0,278
  • Diesel fuel consumption, kg/hour 23
  • Diesel fuel consumption, l/h 28
  • Methane consumption, nm3/hour 30
  • Thermal power, MW (Gcal) 0,2 (0,17)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 1,000
  • Производительность ГВС (+5/+65) 0,03 ГКал, м3/час 0,5
  • Fuel consumption for gas equipment, nm.cub./hour 24
  • Fuel consumption for diesel equipment, kg/hour 19
  • Thermal power, MW (Gcal) 0,5 (0,43)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 1,000
  • Fuel consumption for gas equipment, nm.cub./hour 59
  • Fuel consumption for diesel equipment, kg/hour 56
  • Reaching operating mode, min. 30
  • Thermal power, MW (Gcal) 0,5 (0,43)
  • DHW capacity (+5/+65), m3/hour 1,3
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 1,000
  • Fuel consumption for gas equipment, nm.cub./hour 59
  • Fuel consumption for diesel equipment, kg/hour 56
  • Тепловая мощность, МВт (Гкал 1 (0,86)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 2,000
  • Fuel consumption for gas equipment, nm.cub./hour 118
  • Fuel consumption for diesel equipment, kg/hour 93
  • Reaching operating mode, min. 60
  • Суммарная тепловая мощность, МВт (Гкал) 1 (0,86)
  • DHW capacity (+5/+65), m3/hour 2,6
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 2,000
  • Fuel consumption for gas equipment, nm.cub./hour 118
  • Fuel consumption for diesel equipment, kg/hour 93
  • Тепловая мощность, МВт (Гкал 1,4 (1,2)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 6,000
  • Fuel consumption for gas equipment, nm.cub./hour 177
  • Fuel consumption for diesel equipment, kg/hour 139
  • Reaching operating mode, min. 60
  • Суммарная тепловая мощность, МВт (Гкал) 1,4 (1,2)
  • DHW capacity (+5/+65), m3/hour 4,0
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 6,000
  • Fuel consumption for gas equipment, nm.cub./hour 177
  • Fuel consumption for diesel equipment, kg/hour 139
  • Тепловая мощность, МВт (Гкал 2 (1,72)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 6,000
  • Fuel consumption for gas equipment, nm.cub./hour 236
  • Fuel consumption for diesel equipment, kg/hour 185
  • Reaching operating mode, min. 60
  • Суммарная тепловая мощность, МВт (Гкал) 2 (1,72)
  • DHW capacity (+5/+65), m3/hour 5,3
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 6,000
  • Fuel consumption for gas equipment, nm.cub./hour 236
  • Fuel consumption for diesel equipment, kg/hour 185
  • Тепловая мощность, МВт (Гкал 3 (2,58)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 6,400
  • Fuel consumption for gas equipment, nm.cub./hour 355
  • Fuel consumption for diesel equipment, kg/hour 335
  • Reaching operating mode, min. 60
  • Суммарная тепловая мощность, МВт (Гкал) 3 (2,58)
  • DHW capacity (+5/+65), m3/hour 7,9
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 6,400
  • Fuel consumption for gas equipment, nm.cub./hour 355
  • Fuel consumption for diesel equipment, kg/hour 335
  • Тепловая мощность, МВт (Гкал 4 (3,44)
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 12000
  • Fuel consumption for gas equipment, nm.cub./hour 473
  • Fuel consumption for diesel equipment, kg/hour 371
  • Reaching operating mode, min. 60
  • Суммарная тепловая мощность, МВт (Гкал) 4 (3,44)
  • DHW capacity (+5/+65), m3/hour 10,6
  • Coolant temperature on the boiler circuit, °C +105/+90
  • Coolant temperature on the external heating circuit, °C +95/+70
  • Coolant volume, l (no more, taking into account expansion tanks) 12000
  • Fuel consumption for gas equipment, nm.cub./hour 473
  • Fuel consumption for diesel equipment, kg/hour 371

1 588 200

including VAT 0%
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0Boiler water volume, m
  • Thermal power, MW 0,5
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 0,556
  • Diesel fuel consumption, kg/hour 46
  • Diesel fuel consumption, l/h 56
  • Methane consumption, nm3/hour 59
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0Boiler water volume, m
  • Thermal power, MW 0,5
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 0,556
  • Diesel fuel consumption, kg/hour 46
  • Diesel fuel consumption, l/h 56
  • Methane consumption, nm3/hour 59

1 856 400

including VAT 0%
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,6
  • Thermal power, MW 0,7
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 0,778
  • Diesel fuel consumption, kg/hour 65
  • Diesel fuel consumption, l/h 78
  • Methane consumption, nm3/hour 83
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,6
  • Thermal power, MW 0,7
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 0,778
  • Diesel fuel consumption, kg/hour 65
  • Diesel fuel consumption, l/h 78
  • Methane consumption, nm3/hour 83

2 595 300

including VAT 0%
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,86
  • Thermal power, MW 23 866 $
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 1,11
  • Diesel fuel consumption, kg/hour 93
  • Diesel fuel consumption, l/h 112
  • Methane consumption, nm3/hour 118
  • Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 0,86
  • Thermal power, MW 23 866 $
  • Water temperature not higher, °C 95
  • Thermal power of the burner, not less, MW 1,11
  • Diesel fuel consumption, kg/hour 93
  • Diesel fuel consumption, l/h 112
  • Methane consumption, nm3/hour 118
  • Thermal system, Gcal/time, MW/time 0,15(0,174)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 12
  • The volume of the coolant, m3 0,2
  • Installed power, kW 4
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250
  • Thermal system, Gcal/time, MW/time 0,3(0,348)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 16
  • The volume of the coolant, m3 0,35
  • Installed power, kW 8.5
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250

1 986 500

including VAT 0%
  • Thermal system, Gcal/time, MW/time 0,46(0,54)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 20
  • The volume of the coolant, m3 0,4
  • Installed power, kW 9
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250

2 185 000

including VAT 0%
  • Thermal system, Gcal/time, MW/time 0,65(0,735)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 20
  • The volume of the coolant, m3 0,4
  • Installed power, kW 9
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250
  • Thermal system, Gcal/time, MW/time 0,8 (0,93)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 33
  • The volume of the coolant, m3 0,52
  • Installed power, kW 9
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250
  • Thermal system, Gcal/time, MW/time 1,0 (1,16)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 42
  • The volume of the coolant, m3 0,8
  • Installed power, kW 15
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250

4 209 700

including VAT 0%
  • Thermal system, Gcal/time, (MW/time) 1,5(1,74)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 60
  • The volume of the coolant, m3 1,5
  • Installed power, kW 25
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250
  • Thermal system, Gcal/time, MW/time 2,0(2,32)
  • Efficiency, % not less 90
  • The area of ​​the heat exchanger, m2 110
  • The volume of the coolant, m3 2,5
  • Installed power, kW 36
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250
  • Thermal system, Gcal/time, MW/time 0,03(0,036)
  • Efficiency, % not less 99
  • The volume of the coolant, m3 0,2
  • Installed power, kW 40
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250*
  • Time to exit to mode, min 30
  • Thermal system, Gcal/time, MW/time 0,1(0,120)
  • Efficiency, % not less 99
  • The volume of the coolant, m3 0,8
  • Installed power, kW 125 kW
  • Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
  • Oil heating mode, feed/return, ° C 300/250*
  • Time to exit to mode, min 30

270 400

including VAT 0%
  • A type stationary, horizontal
  • Useful capacity, m3 4
  • Pressure for filling
  • Minimum wall temperature under design pressure, TheWith; minus 20
  • Design wall temperature, TheWith; plus 150
  • Insulation thickness, mm 50
  • Climatic version U-4

437 200

including VAT 0%
  • A type stationary, horizontal
  • Useful capacity, m3 6
  • Pressure for filling
  • Material of manufacture Article 3
  • Maximum temperature °C plus 65
  • Insulation thickness, mm 80
  • Climatic version U-1

820 600

including VAT 0%
  • A type stationary, horizontal
  • Useful capacity, m3 15
  • Pressure for filling
  • Minimum wall temperature under design pressure, TheWith; minus 20
  • Design wall temperature, TheWith; plus 150
  • Insulation thickness, mm 100
  • Climatic version U-1

971 700

including VAT 0%
  • A type stationary, horizontal
  • Useful capacity, m3 25
  • Pressure for filling
  • Minimum wall temperature under design pressure, TheWith; minus 20
  • Design wall temperature, TheWith; plus 150
  • Insulation thickness, mm 100
  • Climatic version U-1

44 600

including VAT 0%
  • Useful capacity, m3 0,6
  • Design pressure, MPa, no more for filling, 0.05
  • Material of manufacture Art. 3 bedroom
  • Tank weight, kg 190
  • Length, mm 2126
  • Width, mm 300
  • Height, mm 1370

62 500

including VAT 0%
  • Useful capacity, m3 1
  • Design pressure, MPa, no more for filling, 0.05
  • Material of manufacture Art. 3 bedroom
  • Tank weight, kg 270
  • Length, mm 2070
  • Width, mm 400
  • Height, mm High capacity silos

254 400

including VAT 0%
  • Useful capacity, m3 5
  • Design pressure, MPa, no more for filling, 0.02
  • Material of manufacture Art. 3 bedroom
  • Tank weight, kg 560
  • Length, mm 2750
  • Width, mm 1860
  • Height, mm 2400

350 500

including VAT 0%
  • Useful capacity, m3 7
  • Design pressure, MPa, no more for filling, 0.02
  • Material of manufacture Art. 3 bedroom
  • Tank weight, kg 750
  • Length, mm 3500
  • Width, mm 1860
  • Height, mm 2400

521 900

including VAT 0%
  • Useful capacity, m3 10
  • Design pressure for filling
  • Climatic version U-1
  • Tank weight, kg 1800
  • Length, mm 3353
  • Width, mm 2576
  • Height, mm 3843

692 400

including VAT 0%
  • Useful capacity, m3 25
  • Design pressure for filling
  • Climatic version U-1
  • Tank weight, kg 2750
  • Length, mm 7151
  • Width, mm 2607
  • Height, mm 3483

88 000

including VAT 0%
  • The tank volume, m3 0,4
  • Design pressure for filling (0.01MPa)
  • Design wall temperature, °C +300
  • Tank weight, kg 180
  • Length, mm 1525
  • Width, mm 678
  • Height, mm 1280

108 700

including VAT 0%
  • The tank volume, m3 1
  • Design pressure for filling (0.01MPa)
  • Design wall temperature, °C +300
  • Tank weight, kg 260
  • Length, mm 2010
  • Width, mm 800
  • Height, mm 1408

129 300

including VAT 0%
  • The tank volume, m3 1,5
  • Design pressure for filling (0.01MPa)
  • Design wall temperature, °C +300
  • Tank weight, kg 316
  • Length, mm 2708
  • Width, mm 800
  • Height, mm 1408

144 900

including VAT 0%
  • The tank volume, m3 2
  • Design pressure for filling (0.01MPa)
  • Design wall temperature, °C +300
  • Tank weight, kg 375
  • Length, mm 2215
  • Width, mm 1018
  • Height, mm 1796

170 600

including VAT 0%
  • The tank volume, m3 3
  • Design pressure for filling (0.01MPa)
  • Design wall temperature, °C +300
  • Tank weight, kg 480
  • Length, mm 2950
  • Width, mm 1018
  • Height, mm 1800

57 600

including VAT 0%
  • Maximum operating pressure, mbar 360
  • Outlet pressure range, mbar 4 – 20
  • Operating ambient temperature, °C -15 ÷ +70
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Solenoid valve class class A, group 2
  • Pressure stabilizer class class A, group 2

75 700

including VAT 0%
  • Maximum operating pressure, mbar 360
  • Outlet pressure range, mbar 4 – 20
  • Operating ambient temperature, °C -15 ÷ +70
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Solenoid valve class class A, group 2
  • Pressure stabilizer class class A, group 2

100 300

including VAT 0%
  • Maximum operating pressure, mbar 360
  • Outlet pressure range, mbar 4 – 20
  • Operating ambient temperature, °C -15 ÷ +70
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Solenoid valve class class A, group 2
  • Pressure stabilizer class class A, group 2

124 200

including VAT 0%
  • Maximum operating pressure, mbar 360
  • Outlet pressure range, mbar 4 – 20
  • Operating ambient temperature, °C -15 ÷ +70
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Solenoid valve class class A, group 2
  • Pressure stabilizer class class A, group 2

146 500

including VAT 0%
  • Maximum operating pressure, mbar 360
  • Outlet pressure range, mbar 4 – 20
  • Operating ambient temperature, °C -15 ÷ +70
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Solenoid valve class class A, group 2
  • Pressure stabilizer class class A, group 2

153 100

including VAT 0%
  • Maximum operating pressure, mbar 360
  • Outlet pressure range, mbar 4 – 20
  • Operating ambient temperature, °C -15 ÷ +70
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Solenoid valve class class A, group 2
  • Pressure stabilizer class class A, group 2

189 500

including VAT 0%
  • Maximum operating pressure, mbar 500
  • Outlet pressure range, mbar 15 – 120
  • Operating ambient temperature, °C -10 ÷ +60
  • Type of gas natural, liquefied
  • Electrical equipment protection degree IP54
  • Control valve type single stage
  • Minimum gas pressure switch B (AC) 24 – 250

91 500

including VAT 0%
  • power, kWt 60,2÷118,0
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~1/220V/50
  • Electrical protection degree IP40

97 700

including VAT 0%
  • power, kWt 83÷166
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~1/220V/50
  • Electrical protection degree IP40

97 700

including VAT 0%
  • power, kWt 50÷160
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 2nd grade
  • Noise level, dB(A) 68
  • Connecting gas fittings above
  • Power supply, Hz ~1/220V/50

108 400

including VAT 0%
  • power, kWt 118,6÷261,0
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~1/220V/50
  • Electrical protection degree IP40

102 700

including VAT 0%
  • power, kWt 60÷205
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 3rd grade
  • Noise level, dB(A) 68
  • Connecting gas fittings above
  • Power supply, Hz ~1/220V/50

122 900

including VAT 0%
  • power, kWt 190÷310
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~1/220V/50
  • Electrical protection degree IP40

129 000

including VAT 0%
  • power, kWt 100÷280
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 3rd grade
  • Noise level, dB(A) 68
  • Connecting gas fittings above
  • Power supply, Hz ~1/220V/50

182 900

including VAT 0%
  • power, kWt 80÷410
  • Power regulation Smooth two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 3rd grade
  • Noise level, dB(A) 77
  • Connecting gas fittings from below
  • Power supply, Hz ~1/220V/50

149 700

including VAT 0%
  • power, kWt 160÷450
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~1/220V/50
  • Electrical protection degree IP40

202 900

including VAT 0%
  • power, kWt 100÷450
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 3rd grade
  • Noise level, dB(A) 76
  • Connecting gas fittings bottom/top
  • Power supply, Hz ~3/380V/50

180 100

including VAT 0%
  • power, kWt 250÷600
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~3/380V/50 Hz
  • Electrical protection degree IP40

255 900

including VAT 0%
  • power, kWt 120÷600
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 3rd grade
  • Noise level, dB(A) 76
  • Connecting gas fittings bottom/top
  • Power supply, Hz ~3/380V/50

236 400

including VAT 0%
  • power, kWt 200÷850
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~3/380V/50 Hz
  • Electrical protection degree IP40

277 700

including VAT 0%
  • power, kWt 130÷850
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 2nd grade
  • Noise level, dB(A) 73
  • Connecting gas fittings bottom/top
  • Power supply, Hz ~3/380V/50

327 500

including VAT 0%
  • power, kWt 285÷1100
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~3/380V/50 Hz
  • Electrical protection degree IP40

436 200

including VAT 0%
  • power, kWt 150÷1200
  • Power regulation Smooth two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 2nd grade
  • Noise level, dB(A) 75,5
  • Connecting gas fittings from below
  • Power supply, Hz ~3/380V/50

376 400

including VAT 0%
  • power, kWt 400÷1300
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~3/380V/50
  • Electrical protection degree IP40

459 700

including VAT 0%
  • power, kWt 170÷1500
  • Power regulation Smooth two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 2nd grade
  • Noise level, dB(A) 79
  • Connecting gas fittings from below
  • Power supply, Hz ~3/380V/50

489 200

including VAT 0%
  • power, kWt 140÷1500
  • Power regulation Modulation
  • Regulation of the gas-air mixture Mechanical
  • Modulation depth 1:4
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 2nd grade
  • Noise level, dB(A) 79

379 400

including VAT 0%
  • power, kWt 510÷1600
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~3/380V/50
  • Electrical protection degree IP40

517 100

including VAT 0%
  • power, kWt 210÷2100
  • Power regulation smooth two-stage
  • mode Intermittent (stop once every 24 hours)
  • Nitrogen oxide emissions 2nd grade
  • Noise level, dB(A) 85
  • Connecting gas fittings from below
  • Power supply, Hz ~3/380V/50

481 000

including VAT 0%
  • power, kWt 800÷2100
  • Power regulation Two-stage
  • mode Intermittent (stop once every 24 hours)
  • Maximum fuel viscosity, cSt 6
  • Diesel fuel atomization Mechanical
  • Power supply, Hz ~3/380V/50
  • Electrical protection degree IP40
  • Inlet gas pressure, kPa 2,5...36
  • Natural gas consumption, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 53
  • Inlet gas pressure, kPa 6...36
  • Natural gas consumption, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 88
  • Inlet gas pressure, kPa 4...36
  • Natural gas consumption, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 88
  • Inlet gas pressure, kPa 8...36
  • Natural gas consumption, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 176
  • Inlet gas pressure, kPa 6...36
  • Natural gas consumption, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 83
  • Inlet gas pressure, kPa 4...36
  • Natural gas consumption, nm3Productivity (at a flow rate in the cylindrical part of 2.5 m/s), m 83

179 115

including VAT 0%
  • Gas inlet pressure
  • Outlet gas pressure
  • Automation kit for steam supply to bunker heating registers
  • Steel 20 GOST 1050
  • Coating gray enamel primer
  • Threaded surfaces conservation lubricant
  • Set of nuts M24
  • Height, m. 6
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 6
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 6
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 8
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 8
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 8
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 10
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 10
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 10
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 12
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 12
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)
  • Height, m 12
  • Climatic version according to GOST 15150 Block-modular boiler house
  • Permissible seismic area no more than 6 points (MSK-64)
  • Allowable wind area no more than 4 (0.48 kPa, SP 20.13330.2016)
  • Mounting method anchor bolts M24x700 (optional delivery)

133 400

including VAT 0%
  • Productivity, m3/h 1
  • Developed pressure, MPa 0,5
  • Self-priming height up to, m. 3
  • Horizontal self-priming distance up to, m. 5
  • Power consumption no more than, kW 1
  • Connectable diameter Du25
  • Length, mm 1008

392 400

including VAT 0%
  • Overall height, m 7,4
  • Height along the platform, m 6,16
  • Weight, kg 1640
  • Site dimensions, m 3.3 x 2.3

143 100

including VAT 0%

198 600

including VAT 0%

228 800

including VAT 0%

285 400

including VAT 0%

285 500

including VAT 0%

285 500

including VAT 0%

519 500

including VAT 0%

Heat centers ZZBO


For uninterrupted year-round operation of concrete plants


Круглогодичная безостановочная работа бетонного завода возможна при обеспечении тепловой энергией технологических процессов производства бетона в холодное зимнее время и соблюдения требований по температурному режиму для управляющей автоматики, нормально функционирующей только при плюсовой температуре. Не следует забывать и о человеческом факторе – замерзающий персонал не работоспособен. При подготовке к зимнему сезону бетонный завод «закутывается» в металлоконструкцию, обшитую съемной теплоизоляцией из сэндвич-панелей, и оснащается специализированной обогревающей системой.


Heated RBU system performs the following functions:

  • heating of aggregates in bins dosing complexes, including the unfreezing of frozen lumps, removing excess moisture and heated to a temperature under the Regulations;
  • hot water before being fed into the mixer;
  • heating production area.

The structure of the concrete plant with a heating system includes:

  • thermal centers provided a steam generator or heat generators;
  • heat coolant delivery to the place of consumption;
  • heating medium - steam or hot air.

Depending on the type of coolant, thermal centers produced by ZZBO are produced in a wide range:

  • steam generator PG-500 (1000, 2000) with a capacity of 500 (1000, 2000) kg of steam per hour with a steam temperature of not lower than 120 degrees C. Thermal agent is heated steam;
  • heat generator TGV-250 (600) with a thermal power of 250 (600) kW and a capacity of 4500 cubic meters. m of air per hour with an air temperature of at least 150 degrees. The heating agent is hot air.

При использовании парогенератора монтируется сеть трубопроводов и регистров для циркуляции парового теплоносителя, в случае теплогенератора монтируются короба для воздушного теплоносителя. Оба типа агрегатов оснащены горелками, сжигающими дизельное топливо.

Работа теплового центра только на жидком топливе имеет свои негативные стороны, поскольку не в каждом регионе солярка доступна плюс в зимнее время возникают затруднения с ее доставкой на объект. Нередко рядом с бетонным заводом проходит магистраль природного газа, который является прекрасным топливом. С учетом данных обстоятельств на ZZBO разработали парогенераторы и теплогенераторы с котлами нового образца, адаптированными под использование газовых горелок Baltur (Italy).


All heating centers supplied by ZZBO are optionally equipped with gas fuel burners. The customer of the ZZBO concrete plant can now, at the ordering stage, choose the type of burner that corresponds to the most available fuel in his region.