110 500
- power, kWt 50÷160
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 2nd grade
- Noise level, dB(A) 68
- Connecting gas fittings above
- Power supply, Hz ~1/220V/50
116 100
- power, kWt 60÷205
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 3rd grade
- Noise level, dB(A) 68
- Connecting gas fittings above
- Power supply, Hz ~1/220V/50
206 900
- power, kWt 80÷410
- Power regulation Smooth two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 3rd grade
- Noise level, dB(A) 77
- Connecting gas fittings from below
- Power supply, Hz ~1/220V/50
169 300
- power, kWt 178÷391
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~1/220V/50
- Electrical protection degree IP40
289 500
- power, kWt 120÷600
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 3rd grade
- Noise level, dB(A) 76
- Connecting gas fittings bottom/top
- Power supply, Hz ~3/380V/50
203 800
- power, kWt 250÷600
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~3/380V/50 Hz
- Electrical protection degree IP40
314 100
- power, kWt 170÷850
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 2nd grade
- Noise level, dB(A) 73
- Connecting gas fittings bottom/top
- Power supply, Hz ~3/380V/50
267 400
- power, kWt 200÷850
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~3/380V/50 Hz
- Electrical protection degree IP40
370 500
- power, kWt 320÷1050
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~3/380V/50 Hz
- Electrical protection degree IP40
493 400
- power, kWt 240÷1200
- Power regulation Smooth two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 2nd grade
- Noise level, dB(A) 75,5
- Connecting gas fittings from below
- Power supply, Hz ~3/380V/50
425 800
- power, kWt 400÷1300
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~3/380V/50
- Electrical protection degree IP40
520 000
- power, kWt 300÷1500
- Power regulation Smooth two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 2nd grade
- Noise level, dB(A) 79
- Connecting gas fittings from below
- Power supply, Hz ~3/380V/50
553 400
- power, kWt 300÷1500
- Power regulation Modulation
- Regulation of the gas-air mixture Mechanical
- Modulation depth 1:4
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 2nd grade
- Noise level, dB(A) 79
429 200
- power, kWt 500÷1600
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~3/380V/50
- Electrical protection degree IP40
584 900
- power, kWt 400÷2100
- Power regulation smooth two-stage
- mode Intermittent (stop once every 24 hours)
- Nitrogen oxide emissions 2nd grade
- Noise level, dB(A) 85
- Connecting gas fittings from below
- Power supply, Hz ~3/380V/50
544 100
- power, kWt 800÷2100
- Power regulation Two-stage
- mode Intermittent (stop once every 24 hours)
- Maximum fuel viscosity, cSt 6
- Diesel fuel atomization Mechanical
- Power supply, Hz ~3/380V/50