Thermal oil boiler TEPLO KTM-0.8
Pump High Temp
2 459 016
Enquire conditions
and delivery time
We'll call you back within 15 minutes
Specify your requirements
Send prices and terms of delivery
| Thermal oil boiler with a heat exchanger in the form of a multi-pass spiral made of hot-rolled pipe DU 50, steel 09G2S, with thermal insulation of the body, covered with a stainless steel sheet with a mirror surface |
|
High-temperature pump ZY Tehnology WRY 80-50-250 for circulating coolant in the boiler-consumer line. Max. pace. liquids 300 °C. Power 22 kW |
| Frequency converter (FC) for smooth start of the circulation pump and speed control |
| Vibration-resistant pressure gauges for visual monitoring of pressure on the boiler flow and return lines |
| Thermal resistance for controlling the heating modes of the coolant on the boiler supply and return lines and at the flue gas outlet |
| Mechanical pressure switch to turn off the pump when the permissible pressure is exceeded |
| Differential pressure switch to protect the circulation pump from “dry running” |
| Pressure meter for visual monitoring of pressure in the furnace |
|
Control panel with regulator “Thermodat-11M6”, with automatic heating of oil according to specified temperature settings and selection of operating mode (“Heating”, “Stop”, “Circulation”), automatic shutdown of the boiler when the pressure is exceeded, burner failure in an IP54 enclosure. Adjustment of the coolant temperature using an on-off or proportional-integral differential (PID) control law to accurately maintain the set parameters (Option available when working with a modulating burner) |
| Shut-off valves: Wedge gate valves type 30S41NZH |
| Degasser for removing gases and air from the coolant |
| Heat-resistant chimney DN 350 with spark arrestor, height 5.7 m |
| Passport and Manual |
| Burner gas Baltur TBG 120P |
| Gas fittings |
| Аксиальный компенсатор BTGA 2" |
| Diesel burner Baltur TBL 120P |
| Fitting kit for diesel burner |
| Nozzle 9.50x60 |
| Горелка газовая FBR GAS P70/2 CE TL + R. CE D1"1/4-S (756 кВт) |
| Diesel burner FBR FGP 70/2 TC (830 kW) |
| Control panel based on the Segnetics SMH4 controller with a touch screen - a single control interface: programmable operating algorithms, advanced monitoring and diagnostic functions with a detailed event log. Intelligent control with centralized parameter setting and the ability to integrate into larger automation systems. Protection degree IP54, climatic version UHL-4. |
| Sandwich chimney made of stainless steel, with insulation 50 mm thick |
| Block box: metal frame sheathed on both sides with corrugated sheets, 80mm insulation, vapor barrier, PVC window, door, lighting, ventilation grilles, roof deflector |
| Oil injection station SZM-0.6 |
| Rest of expansion tank ERB-6 |
| Thermal insulation of shut-off valves |
| Expansion tank 0.4 cubic meters |
| Expansion tank 1.0 cubic meters |
| Expansion tank 1.5 cubic meters |
| Expansion tank 2.0 cubic meters |
| Expansion tank 3.0 cubic meters |
| Diesel fuel tank BDT-0.6 |
| Tank for diesel fuel BDT-1 |
| Diesel fuel tank BDT-5 |
| Diesel fuel tank BDT-7 |
| Tank for diesel fuel BDT-10 |
| Tank for diesel fuel BDT-25 |
Thermal oil boiler TEPLO KTM-0.8 is designed for heating thermal oil to a temperature of +300 °C with an excess pressure of up to 0.2 MPa. It is used to supply heat to technological processes for pumping bitumen and fuel oil using a coaxial pipeline (satellite heating of pipelines), heating bitumen and fuel oil tanks using closed registers, and are also used in the woodworking, petrochemical, metallurgical and light industries.
[parent] => 45 [count] => 6 [filter] => raw )
The operation of the oil heating station can be carried out (depending on the selected burner) on both gas and diesel fuel. Additionally, TEPLO KTM in diesel version can be equipped with a fuel tank with the volume necessary for autonomous operation of the unit at the Customer’s site.
[parent] => 45 [count] => 6 [filter] => raw )
The TEPLO KTM thermal oil boiler can be supplied either on a frame (for indoor installation) or in an insulated block container (for outdoor installation).
[parent] => 45 [count] => 6 [filter] => raw )
The automatic control mode makes it easy to start the boiler and reach rated production capacity in a short time.
[parent] => 45 [count] => 6 [filter] => raw )
Read more about KTM thermal oil boilers from TEPLO
The price for the thermal center is presented without a burner
- Not subject to registration with Rostekhnadzor
- Italian components (BALTUR or F.B.R. burners, valves, safety valves, pumps)
- Automatic control
- Mobile installation, completely autonomous
- Casing stainless steel boiler
- Transport dimensions
- 2-year warranty
Technical Features
- Thermal system, Gcal/time, MW/time 0,8 (0,93)
- Efficiency, % not less 90
- The area of the heat exchanger, m2 33
- The volume of the coolant, m3 0,52
- Installed power, kW 9
- Power Power 3F, V/Hz Reject hopper capacity (at a density of 1.8 t/m³), m³ (t)
- Oil heating mode, feed/return, ° C 300/250
- Time to exit to mode, min 30
- Oil heating mode, supply / return, max, 10
- Diesel burner Baltur 1050
- Diesel consumption fuel, kg/hour 68
- Natural gas consumption, nm3/hour 87
- Length, m 4,6
- Width, m 2,4
- Working height (transport), m 6,09 (2,36)
- Weight, kg 3670
- Diesel burner Baltur U3.1
- Kinematic viscosity of isothermal oil at 40 OKinematic viscosity of isothermal oil at 40 Kinematic viscosity of isothermal oil at 40
- Kinematic viscosity of isothermal oil at 40 OKinematic viscosity of isothermal oil at 40 2…10
- Kinematic viscosity of isothermal oil at 40 O from “Bulgaria" 200
- Boiling point of isothermal oil in the open air, not less than, O from “Bulgaria" 300
- Boiling point of isothermal oil in the open air, not less than, O from “Bulgaria" 350
- Connection of branch pipes of supply and return flanged, mm Two-100
- Connection of branch pipes of supply and return flanged, mm Connection of branch pipes of supply and return flanged, mm
- Connection of branch pipes of supply and return flanged, mm Connection of branch pipes of supply and return flanged, mm
- The horizontal level of the expansion tank must be equal to or higher than the highest point of the entire heating line, as open type expansion tank
Quality
certificates
Products
in stock
Individual configuration
with prices for each item
Mobile
commissioning
available
Worldwide
delivery
in trucks or containers
Geography of supplies 2011-2026
Own production, in-stock products and
professional team allow us guarantee
most competitive prices, shortest
possible delivery time and high-quality goods












