Hot water boiler KVA-1.5 Gn/LZh
1 335 500
Enquire conditions
and delivery time
We'll call you back within 15 minutes
Specify your requirements
Send prices and terms of delivery
Manometer electrocontact DM2010Sg, 0-0,6MPa range |
Manometer showing the TM-510R.00, 0-0,6MPa range |
Safety valve 17s28nzh DN50 / 80, pH = 0.5 MPa |
Temperature sensor type Pt100 RTD |
Crane grooved ball DN15 |
Crane grooved ball DN25 |
Ruff for cleaning fire tubes |
boiler control cabinet |
Passport and operating instructions on the boiler |
Burner gas Baltur TBG 210P |
Gas fittings MM415 A20C-R6/4 |
Адаптер горелка/рампа (переходник) 2"Mx1"1/2F |
Аксиальный компенсатор BTGA 1"1/2 |
Diesel burner Baltur TBL 210P |
Форсунка 15,00х45 |
Горелка газовая FBR GAS P150/2 CE TL |
Горелка дизельная FBR FGP 190/3 TL |
Burner combined gas-diesel |
Burner for fuel oil (spent fuel) |
The block container with viewing windows |
Diesel fuel tank BDT-0.6 |
Tank for diesel fuel BDT-1 |
Diesel fuel tank BDT-7 |
Tank for diesel fuel BDT-10 |
Tank for diesel fuel BDT-25 |
Heating hot water boiler KVA-1.5Gn/LV used as an independent thermal unit for heating coolants in open and closed circuits of heating systems, and as part of thermal systems with a closed circuit when organizing heating and hot water supply (DHW) of civil and industrial premises with a nominal pressure in the primary circuit of up to 0.6 MPa and temperature up to 105 °C. Coolants can be water, solutions based on propylene and ethylene glycol (antifreeze) with a concentration of up to 50%.
Boilers can be equipped burnersoperating on various types of fuel (diesel, gas, fuel oil, heating oil)
boiler KVA-1.5Gn/LV as part of a boiler room, can be supplied either on a frame or in a block box. Climatic modification UHL-1 when supplied in a block box; when supplied without a block box, climatic modification UHL-3.
KVA hot water boilers have a TR TS 016 certificate, a TR TS declaration 001, 010, 020 and voluntary certification according to the GOST R system.
The price for the thermal center is presented without a burner
- To provide hot water and heating
- Start-up time – 15 minutes
- Automatic control, high efficiency - 90%
- Convenient service
- Low fuel consumption
Technical Features
- Thermal power, MW 1,5
- Design pressure, MPa 0,6
- Test pressure, MPa 0,9
- Internal heating area, m2 35
- Boiler internal volume, m3 1.8
- Firebox volume, m3 1,449
- Connecting diameter of supply and return, DN, mm 150
- Connecting size of a drain branch pipe, DN, mm 32
- Thermal power of the burner, MW 1667
- Reject hopper capacity (at a density of 1.8 t/m³), m³ (t) 1,29
- Diesel fuel consumption, kg/hour 72…144
- Methane consumption, nm3/hour 42…223
- Time to exit to mode, min 20-40
- Boiler weight (without attachments), kg 3,200
- Length, mm 3310
- Width, mm 1620
- Height, mm 1900
Quality
certificates
Products
in stock
Individual configuration
with prices for each item
Mobile
commissioning team
available
Worldwide
delivery
in trucks or containers